The power indicator is out of sync with the power supply state. There are a handful of factors that play into this when using Internal Sensing. 
 Use GPIO or System Command Sensing for the best experience.
- 
GPIO Sensing not working right and octoprint.plugins.psucontrol - ERROR - [Errno None] Line bias configuration not supported by Kernel version x.xxappears in the log file.Linux Kernel version 5.5 or greater is required for input bias (pull up/down) support. Upgrade to Kernel 5.5+ or use PSUControl-RPiGPIO if on a Raspberry Pi. 
- 
GPIO Switching and Sensing using the same pin number does not work. Currently there is no way to treat an output as an input. This worked in previous version (<1.0.0) of PSU Control due to a bug which overwrote a sense pin as a switching pin. Support may be added at a later date but until then you can either use Internal sensing or use PSUControl-RPiGPIO if on a Raspberry Pi. 
- 
OSError: [Errno 16] Device or resource busy / Exception while setting up GPIO pin Ensure that the configured device/pin are not already in use. You can confirm this by running gpioinfo gpiochip#- See #188
- 
My relay isn't working, is stuck on/off, or behaved erradically.
Make sure you are using a 3.3V logic level relay or a 5V logic level relay that will work with 3.3V logic levels. Some 5V logic level relays can be modified to support 3.3V logic levels. 
Logs are a critical part of solving bugs. Below are the steps for gathering and providing useful logs.
- In OctoPrint, go to Settings -> Logging -> Logging Levels.
- Ensure that octoprint.plugins.psucontrol is listed and set to DEBUG. If you are using a sub-plugin for Switching or Sensing be sure to enable DEBUG logging for that as well. Sub-plugins are generally prefixed with octoprint.plugins.psucontrol ( Example: octoprint.plugins.psucontrol_rpigpio ). If you are not using any sub-plugins but have them installed be sure that they are disabled or uninstalled.
- Serial logging may also be helpful depending on the issue. You may skip this step if desired but be ready to provide this starting from step 1 should it be requested.
 To enable go to Settings -> Serial Connection -> Serial Logging. From there you can check Log communication to serial.log.
- Restart OctoPrint
- Note the time and reproduce the issue.
- Go to Settings -> Logging.
- Download octoprint.log and depending on step 3 download serial.log
- Review the log for any helpful information that might solve the issue.
- Attach the log files to the ticket and provide as much information as possible including the times noted and anything helpful you found when reveiwing the logs.