…of the pvwatts model
…ake code apart to hook it up to the cec module model
…ndia inverter ac power function so that not all results must be retrieved
removed my previously added outputs for estimated system configuration because they are misleading, and instead added outputs for timeseries shading derates. added tests of these derates. also updated logic for calculating system layout in pvwattsv8, and updated tests with new results. one test still throwing SEH error.
sjanzou
left a comment
There was a problem hiding this comment.
Choose a reason for hiding this comment
The reason will be displayed to describe this comment to others. Learn more.
Looks good, thanks for adding the tests!
mjprilliman
left a comment
There was a problem hiding this comment.
Choose a reason for hiding this comment
The reason will be displayed to describe this comment to others. Learn more.
LGTM. Got an SEH exception on the NonAnnual test on Windows but I believe we said those are fine.
|
Yes @mjprilliman , I got that same exception if I ran the test through Test.exe but not if I ran it through the Test Explorer on Windows, which we think is a known issue with all the NonAnnual tests. Thanks both for your reviews! |
This pull requests adds PVWattsV8 as detailed in, and fixes #629 . All tests are passing. Additional comparisons between v5 results and v8 results will be detailed in a technical report.